Flashing safety device FSL

 

Power supply 1 ph 115-230/50-60 o 3ph 400/50-60 V/Hz, dimensions HWLxD 46x145x88mm

 

Features Unit FSL
Power supply V/Hz 1ph 115-230/50-60 or 3ph 400/50-60
FUNCTIONS
Power on Phase sequence Phase loss Yes/No Yes
Signal - n° 3 LED red
Contact for lamp Yes/No Yes
Contact type - NC
Max current A 5
Service life Cycles > 25.000
Auxiliary Contact Yes/No No
Contact type -
Max current A -
Service life Cycles -
Probe extension mm Adjustable 11-16
Casing - Poly-carbonate Yellow
Connection on terminals mm2 n. 8×4
Mounting - Adjustable fixing bracket 125 mm interlock
Protection degree EN60529 - IP20
Protection class - I
Operating/Storage temperature °C(°F) -10 +70 (+14 +158)/-20 +80(-4 +176)
Installation position - Variable
Dimensions HxWxD mm 34x112x68 (+16)
Weight kg 0.15
Package dimensions HxWxD mm 46x145x88
Conformity - CE